
 
YuFeng kiln interpretation restart after fault parking 
  Rotary kiln equipment failure restart after stopping refers to an emergency stop after firing system troubleshooting, still   
  			maintain a certain temperature kiln startup . A restart after a low temperature kiln as the kiln should be turned at low temperature kiln fuel injection device using the flame point , after starting coal injection system , coal rate case should be flexible depending on the kiln . 2 , restart the kiln at high temperature high temperature kiln , coal can be injected directly into the ignition , PCI should be preceded by a rotary kiln , the higher the temperature of the bottom portion of the clinker is then blown into the first turn coal powder. 3 , ignition calciner kiln usually due to high temperature exhaust gas temperature and C4 materials , burning pulverized coal in calciner can . For the first time in front of the main kiln firing , feeding process , the actual operation can be applied flexibly in accordance with the principle of ensuring a successful ignition feed . 
                Previous:  Kiln fire occurs due to the reason and method of operation to be taken  | 
| 
 Copyright © 2012 by Zhengzhou Yufeng Heavy Machinery Co.,Ltd All rights reserved 
Tel/FAX: 86-371-60395600    Whatsapp 86-13526817088    Email- sale@yufchina.com
    	
     
		 	
	         
 |